Home
Girard Home
Hatebur Home
Services
Tool Development
Development Center
Training
Hotformers
General Overview
AMP20 & AMP30 >>
General Overview
Typical Setup
Anatomy
About The Bars
Three Stations
Long Lasting Tools
Transer System
Operation
Accessories
Hot/Cold Process
ESA60/ESA600
AMP20 Specifications
AMP30 Specifications
AMP40 >>
General Overview
Design Overview
Four Stations
Transfer Sstem
Ejectors
Control & Operation
Quick Change
Machine Specifications
AMP50 & AMP70 >>
General Overview
Bar Stock
Hotmatic Design
Indepth Design
Feed Rolls
Shearing Stations
4 Stations
Accurate Transfer
Ejectors
Cooling
Fast Tool Change
Operation
Combination Forging
AMP50 Specifications
AMP70 Speicifications
Coldformers
Design Features >>
General Overview
Coldmatic Design
Shearing System
Five Forming Stations
Enhanced Grippers
Enhanced Ejectors
Operation
Quick Change System
Why Hatbur's Better
Machine Speicifications >>
AKP3-5
AKP4-5
AKP5-5
History
GIRARD HOME
>>
HATEBUR
>>
HOTMATICS
>>
AMP 50 AND AMP 70
>> MACHINE SPECS AMP 70
Technical Data for Hotmatic Hotformer: AMP 70 and AMP 70 XL
AMP 70 (XL)
(metric)
AMP 70 (XL)
(English)
>>> Working Range
--
--
Initial weight
0.4 - 5.0 kg
.90 - 11 lb
Maximum outer diameter for round parts
145 mm (165 mm)
5.71 in (6.50 in)
Maximum outer diameter for combination blanks
132 mm
4.8 in
Bar diameter
36 - 75 mm
1.4 - 3.0 in
Cut-off length
50-150 mm
1.97 - 5.91 in
>>> Performance Data
--
--
Strokes per minute (infinitely variable)
50-80
50-80
Total tonnage
15000 kN
15000 kN
Drive Motor
350 kW
350 kW
Tooling: (Die diameter)
--
--
Forming stations
4
4
1st station
220 mm
8.66 in
2nd station
290 mm (270 mm)
11.42 in (10.63 in)
3rd station
290 mm (310 mm)
11.42 in (12.20 in)
4th station
270 mm (250 mm)
10.63 in (9.84 in)
>>> Strokes
--
--
Main slide
320 mm
12.60 in
Die ejectors
150 mm
5.91 in
Punch ejectors
50 mm
1.97 in
>>> Utility Requirements
--
--
Electrical:
--
--
Power supply
550 kVA
550 kVA
Cooling Water:
--
--
Pressure
6 bar
87 psi
Maximum flow rate (depends on forging)
120 m^3/h
31700 US gal/h
Compressed Air:
--
--
Pressure
5.5 - 10 bar
80-145 psi
Consumption (noncompressed state)
4 Nm^3/h
140 ft^3/h
>>> Utility Requirements
(Dimensions with noise abatement cabin and operator platform, not including heater, conveyor, tool block changer)
--
--
Length
13600 mm
535 in
Width
9600 mm
378 in
Height
4450 mm
175 in
Feed line above floor
1500 mm
59 in
Weight
187 t
412000 LB
BACK TO AMP 50 and AMP 70 MAIN PAGE <<<<<<<<<