Home
Girard Home
Hatebur Home
Services
Tool Development
Development Center
Training
Hotformers
General Overview
AMP20 & AMP30 >>
General Overview
Typical Setup
Anatomy
About The Bars
Three Stations
Long Lasting Tools
Transer System
Operation
Accessories
Hot/Cold Process
ESA60/ESA600
AMP20 Specifications
AMP30 Specifications
AMP40 >>
General Overview
Design Overview
Four Stations
Transfer Sstem
Ejectors
Control & Operation
Quick Change
Machine Specifications
AMP50 & AMP70 >>
General Overview
Bar Stock
Hotmatic Design
Indepth Design
Feed Rolls
Shearing Stations
4 Stations
Accurate Transfer
Ejectors
Cooling
Fast Tool Change
Operation
Combination Forging
AMP50 Specifications
AMP70 Speicifications
Coldformers
Design Features >>
General Overview
Coldmatic Design
Shearing System
Five Forming Stations
Enhanced Grippers
Enhanced Ejectors
Operation
Quick Change System
Why Hatbur's Better
Machine Speicifications >>
AKP3-5
AKP4-5
AKP5-5
History
GIRARD HOME
>>
HATEBUR
>>
HOTMATICS
>>
AMP 50 AND AMP 70
>> MACHINE SPECS AMP 50
Technical Data for Hotmatic Hotformer: AMP 50 XL
AMP 50 XL
(metric)
AMP 50 XL
(English)
>>> Working Range
--
--
Initial weight
.17 - 2.0 kg
.37 - 4.42 lb
Maximum outer diameter for round parts
104 mm
4.09 in
Maximum outer diameter for combination blanks
87 mm
3.43 in
Bar diameter
28-55 mm
1.10 - 2.17 in
Cut-off length
32-110 mm
1.25 - 4.33 in
>>> Performance Data
--
--
Strokes per minute (infinitely variable)
60-100
60-100
Total tonnage
8000 kN
8000 kN
Drive Motor
170 kW
170 kW
Tooling: (Die diameter)
--
--
Forming stations
4
4
1st station
160 mm
6.30 in
2nd station
215 mm
8.46 in
3rd station
215 mm
8.46 in
4th station
200 mm
7.87 in
>>> Strokes
--
--
Main slide
240 mm
9.45 in
Die ejectors
90 mm
3.54 in
Punch ejectors
35 mm
1.38 in
>>> Utility Requirements
--
--
Electrical:
--
--
Power supply
350 kVA
350 kVA
Cooling Water:
--
--
Pressure
6 bar
87 psi
Maximum flow rate (depends on forging)
70 m^3/h
18500 US gal/h
Compressed Air:
--
--
Pressure
5.5-10 bar
80-145 psi
Consumption (noncompressed state)
3 Nm^3/h
100 ft^3/h
>>> Utility Requirements
(Dimensions with noise abatement cabin and operator platform, not including heater, conveyor, tool block changer)
--
--
Length
7500 mm
398 in
Width
5220 mm
305 in
Height
2650 mm
126 in
Feed line above floor
1300 mm
51.2 in
Weight
84 t
198000 lb